Pressure transducer P1AP

Overview

Digital pressure transducer PATROL (P1AP) is a telementry-enabled, battery powered pressure sensor, which is primarily used to measure pressure in distribution pipes of gasses or liquids and sending this measured data over the air into centralized measurement systems such as SCADA.

Wireless communication of te transducer is provided utilizing one of the LoRaWAN, Sigfox, Bluetooth or ZigBee (XBee / 805.15.4) technology using various RF frequency spectrums.

Detailed description

Application

Vo všeobecnosti je tlakový prevodník typu P1AP určený na meranie absolútneho tlaku, podtlaku, pretlaku alebo výšky hladiny meraného média, ktoré nereaguje s nehrdzavejúcou oceľou DIN 1.4301, resp. AISI 304, resp. X5CrNi18 10 z ktorej je vyrobené púzdro prevodníka. Meraný tlak je v prevodníku prevedený na digitálnu formu, matematicky upravený a sériovou linkou odoslaný do prenosového systému SENTRY. Konštrukcia prevodníku a možnosť zvýšeného IP krytia, umožňuje jeho požitie aj pri sťažených poveternostných podmienkach.

V pamäti prevodníku sa uchovávajú aj všetky požiadavky na meracie miesto, názov meracieho miesta, frekvenciu merania a prenosu, prípadne iné identifikačné parametre, čo umožňuje so snímačom použitie ľubovoľnej prenosovej jednotky typu SENTRY.

Mechanical information

Prevodník je umiestnený v robustnom kovovom obale z nehrdzavejúcej ocele. Do meraného systému sa pripája pomocou procesného pripojenia. Ku komunikačnému systému SENTRY sa pripája pomocou klúčovaného konektoru s pripojovacou maticou z ktorého je aj napájaný. Plastové púzdro prevodníka je vyrobené z plastu typu ASA - upravený plast typu ABS z odolnostou voci UV ziareniu.

Technical parameters

Type of measurement absolute pressure, overpressure, underpressure
Maximum range of measurement 0 - 60MPa
Temperature of measured medium min. -40°C, max. +125°C
Measurement precision0,1% from measured range for pressures more or equal to 25kPa
0,25% from measured range for all pressures;
this combined precision accounts for non-linearity of measurement, hysteresis and reprodukovateľnosť
Additional error due to ambient temperature less than 0,03 %/10°C in the range of 0 to +60 °C
less than 0,03 %/10°C in the range of -20 to +60°C
Long-term precision stability additional error of less than 0,15% of range per year
Recommended calibration frequencyevery two years
Power supplyuser replaceable battery: 3.6V LiSOCl2 “D” size (recommended SAFT LS33600 or LSH20)
Wireless uplink technologyBluetooth, LoRaWAN, Sigfox, XBee, ZigBee, 802.15.4, Bluetooth LE
Process attachment M20x1,5; G½; G¼; other on request
Material of process attachmentDIN 1.4301 (AISI 304 / X5CrNi18 10) stainless steel
Material of the dialAnodized aluminium
Isolation resistance at 500VRIZ > 2 M Ohm
IP protection grade according to (IEC 60 529) EN 60 529IP 65

Weight and dimensions

Weight ex. battery:

Dimensions in [mm]

Software

The following documentation details the packet format used in LoRaWAN version of the device. Example parser is available on the following link: https://github.com/moirelabs/patron_tools

Markings

Information included on the label:

  • Manufacturer
  • Unit order code
  • Measurement range and measurement precision
  • Serial number
  • IP rating

Ordering

Order shall contain the following information:

  • Date and internal number of the order
  • Name and address (including VAT number where appropriate)
  • Order number assembled from order tables including number of units and requested delivery date
  • Type of delivery
  • Optional extras to include (for example high pressure shock damping filter)

Packaging

Sensors are approprietly packed individually into padded cartons.

The packaging includes all information required for proper use and servicing of the equipment.

Order information

Measurement range (R)

R0 0-2.5 kPa
R1 0-4 kPa
R2 0-6 kPa
R3 0-10 kPa
R4 0-16 kPa
R5 0-25 kPa
R6 0-40 kPa
R7 0-60 kPa
R8 0-100 kPa
R9 0-160 kPa
R10 0-250 kPa
R11 0-400 kPa
R12 0-600 kPa
R13 0-1 MPa
R14 0-1.6 MPa
R15 0-2.5 MPa
R16 0-4 MPa
R17 0-6 MPa
R18 0-10 MPa
R19 0-16 MPa
R20 0-25 MPa
R21 0-40 MPa
R22 0-60 MPa
R23 80-520 kPa
RX special - on request
R0 NB-IoT - band 20
R1 LoRaWAN - 868MHz
R2 Bluetooth - 2.4GHz
R3 XBee - 2.4GHz
R4 802.15.4 - 2.4GHz
R5 Sigfox
RX special - on request

Measurement precision (P)

P0 0.1%
P1 0.25%
P2 0.4%
P3 0.5%
PX special - on request

Type of measurement (M)

M0 absolute pressure against vacuum
M1 underpressure
M2 overpressure
MX special - on request

Max ambient temperature (W)

W0 min. -20°C max. +60°C
WX special - on request

Mounting thread (T)

T0 M20x1.5
T1 G1/2
T2 G1/4
TX special - on request

Intake nozzle type (N)

N0 standard
NX special - on request

Installation

The manometer is screwed on to the measurement place with appropriate spanner (24mm). The inner thread on the measurement place and manometer must match! Tightness of the connection is ensured by appropriate gasket – not part of the delivery. The body of the manometer must not be used for tightening of the manometer to the measured place. Always use spanner and dedicated clamp nut.

END OF DOCUMENT